Dimensions
| Touchbar height to finished floor | 41″ (1043mm) at center |
| Touch bar projection - neutral | 2 1/2″ (64mm) |
| Touch Bar Projection - depressed | 1 3/4″ (45mm) |
| center case | 8 1/2″ x 2 1/2″ x 2″ (216mm x 69mm x 52mm) |
| Device length - Short 3′ (914mm) | 2′2″ x 3′ (840mm to 914mm) door size |
| Device Length - Long 4′ (1219mm) | 2′9″ to 4′ (1145mm to 1219mm) door size |
Minimum Stile Requirements
4″ escutcheon trims & 4 1/2″ for thumbpiece and rose trims.
Double Door – 4 1/2″ Min. Stile

239 Strike – 418 Mullion

239 Strike – 424 Mullion
4 5/8″ Min. Stile
Single Door – 4 1/2″ Min. Stile

9860 & F9860 Series
Dimensions
| Touchbar height to finished floor | 41″ (1043mm) at center |
| Touch bar projection - neutral | 2 1/2″ (64mm) |
| Touch Bar Projection - depressed | 1 3/4″ (45mm) |
| center case | 8 1/2″ x 2 1/2″ x 2″ (216mm x 69mm x 52mm) |
| Device length - Short 3′ (914mm) | 2′2″ x 3′ (840mm to 914mm) door size |
| Device Length - Long 4′ (1219mm) | 2′9″ to 4′ (1145mm to 1219mm) door size |
| panic grade top & bottom latch case | 3 15/16″ x 2 1/8″ x 1 3/8″ (100mm x 52mm x 42mm) |
| Fire Grade top latch case | 3 15/6″ x 2 11/16″ x 2 1/16″ (100mm x 68mm x 53mm) |
| Fire grade Bottom latch case | 3 15/16″ x 2 1/8″ x 1 3/8″ (100mm x 52mm x 42mm) |
| Top and bottom rod length for 36″ x 84″ doors | top rod 43 1/4″ (1100mm), bottom rod 37 3/4″ (960mm) |
| top and bottom rod length for 48″ x 96″ doors | top rod 53 1/16″ (1350mm), bottom rod 37 3/4″ (960mm) |
| vertical rods | 1/2″ (13mm) round tubing |
Minimum Stile Requirements
Double door - with two vertical rod type exit devices.

3 1/2″ Min. Stile
LBR 9860 & F9860 Series
Specifications:
- LBR - No bottom strike. Free access for wheel chairs, stretcher and cars therefore eliminates tripping potential and disfiguration of floors due to dragging of bottom bolts.
- For Doors - 1-3/4" standard. 3-3/4" minimum stile width required for single door application. 3-1/2" minimum stile width required for double door application. Lever, thumbpiece and escutcheon trims available.
- Chassis - Nonferrous ally (Panic Grade), steel (Fire Grade)
- Cover - Brass, bronze or stainless steel. Covers stock hollow metal doors with 161 cutout.
- Mounting - Furnished with wood and machine screws. Thru bolts are standard packaging on fire rated devices. Thru bolts are included and standard packaging on fire rated devices.
- End Cap - Brass, bronze or stainless steel construction.
- Alarm - Available. Prefix "Alrm" before part #.
- Hand - Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
- Latch Bolt - Stainless steel
- Spring - Stainless steel.
- Auxillary Spring Latch - Auxiliary spring loaded latchbolt is installed in the lower edge of eh door, when exposed to fire latchbolt releases keeping the door closed and regulated.
- ANSI Standard - A156.3, Grade 1.
- Rail Assembly - Heavy gauge brass, bronze or stainless steel.
- Strike - See Strike page.
- Dogging Feature - Allen-type key furnished standard on non-fire labeled devices. Cylinder dogging available.
- UL and ULC Listed - All Series for panic. LBR Series for fire exit hardware for all types of 8′ x 8′ double doors including double egress for up to 3 hour metal, 1-1/2" hour wood doors fire labeled installations. Conforms to standards UL10C and UBC 7-2-1997 codes.
- Finish - Architectural plated finishes. See bottom of Alarm Exit Hardware for available finishes.
- Door Size - LBR 9860V3684 and LBR F9860V3684 for 36" x 84" doors. LBR 9880V4896 and LBR F9880V4896 for 48" x 96" doors. LBR 9890V3696 and LBR F9890V3696 for 36" x 96" doors.
Dimensions:
| Touchbar height to finished floor | 41" (1043mm) at center |
| Touch bar projection - neutral | 2 1/2" (64mm) |
| Touch Bar Projection - depressed | 1 3/4" (45mm) |
| center case | 8 1/2" x 2 1/2" x 2" (216mm x 69mm x 52mm) |
| Device length - Short 3′ (914mm) | 2′2" x 3′ (840mm to 914mm) door size |
| Device Length - Long 4′ (1219mm) | 2′9" to 4′ (1145mm to 1219mm) door size |
| panic grade top & bottom latch case | 3 15/16" x 2 1/8" x 1 3/8" (100mm x 52mm x 42mm) |
| Fire Grade top latch case | 3 15/6" x 2 11/16" x 2 1/16" (100mm x 68mm x 53mm) |
| Top rod length for 36" x 84" doors | top rod 43 1/4" (1100mm) |
| top rod length for 48" x 96" doors | top rod 53 1/16" (1350mm) |
| vertical rods | 1/2" (13mm) round tubing |
Minimum Stile Requirements
Double door - with two vertical rod type exit devices.

3 1/2" Min. Stile
Selector Chart:
| Single Door | Pairs of Doors without Mullion |
|---|---|
![]() Vertical Rod Type or Rim Type |
![]() 2 Vertical Rod Type |
| Surface applied 2 point lock. Surface application. | Surface applied 2 point locking both doors. Each door active same direction. Do not use with overlapping astragal. |
| Pairs of Doors with Mullion | Pairs of Doors without Mullion |
![]() 2 Rim Type With Mullion |
![]() 1 Vertical Rod and 1 rim Type |
| Two independent active doors with full double door openings when required. Same direction. | Both devices are surface applied. A coordinator and overlapping strike is recommended. |
| Pairs of doors without Mullion | Handing |
![]() 2 Vertical Rod type |
![]() |
| Double egress surface applied. 2 point locking both doors opposite directions. |
Fire Exit Hardware
|
|||||||||||||||||||||||
| All fire rated exit devices in all applications, are also labeled for (B) 1-1/2 hour, (C) 3/4 hour, (D) 1 hour, (E) 3/4 hour. All fire exit hardware meet UL10C and UBC 7-2-1997 codes. | |||||||||||||||||||||||
Lever Design
|
||||||||||||||||
|
||||||||||||||||
|
When ordering "AT" and "SPA" designs, prefix design name before part number. Example: ENTOOL in "AT" design is ATENTOOL. Keyway Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders. |
|||||||||||||||
|
|
||||||||||||||||
| Construction | ||||||||||||||||
|
Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible. Hardened steel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices. Finishes Escutcheon Dimensions 2 5/16" width x 8 1/2" length. Lever length: 4 3/4". Fits and covers 2 1/8" 161 cutout. Keyway Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.
|
|
|||||||||||||||
Pull Design
|
||||||||||||||||
Thumbpiece Trim
|
||||||||||||||||
|
Finishes Door Thickness Standard 1 3/4". Prefix THI before part number for 2 1/4 thick doors. Keyway Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders. |
|||||||||||||||
|
Interchangeable Core - Interchangeable core locks will accept compatible 6 or 7 pin cores with Best, Falcon and Arrow. Indicated by "IC" |
||||||||||||||||
Strikes
| (All Strikes are black nylon coated) | |
| For use with 9860 Vertical Rod Exit Device
For use with 9800 Rim Type Exit Device
Overlapping Strike
|
For use with F9860 Vertical Rod Fire Rated Exit Device
For use with F9800 Rim Fire Exit Device
Additional Strikes
|
| Accessories | |
| Mullions
Lockable and electric lockable mullions are available on request. |
|
|
|
|
| Additional Rods | Cylinder Dogging Kits |
|
Vertical rod for 10 feet high doors available on non fire rated vertical rod devices only. Use part # VRRD-10. |
Prefix "CD" before part#. Available for all 9800 Series devices except fore exit hardware. Cylinder dogging with a mortise cylinder is located on the mounting insert locks bolt in retracted position. 27" minimum door width is required. To order kit only us part# 36CYLD9800 for 36" and 48CYLD9800 for 48" devices. Specify finish. |
| Glass Bead Shim Kits | |
|
801 - For rim type, 1/8" thick |
|
Alarm Exit Hardware
| Rim Type Exit Devices | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ALRM 9800 EO36 - Alarm rim type 36" door (panic grade) Vertical Rod Type Exit Devices Prefix "Alrm" before part # |
Features:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|