9800 & F9800 Series 9860 & F9860 Series LBR 9860 & F9860 Series

Selector Chart Fire Exit Hardware

Lever Design

   
Pull Design Thumbpiece Trim Strikes
Alarm Exit Hardware    

9800 & F9800 Series

Back to top

Dimensions

Back to top

Touchbar height to finished floor 41″ (1043mm) at center
Touch bar projection - neutral 2 1/2″ (64mm)
Touch Bar Projection - depressed 1 3/4″ (45mm)
center case 8 1/2″ x 2 1/2″ x 2″ (216mm x 69mm x 52mm)
Device length - Short 3′ (914mm) 2′2″ x 3′ (840mm to 914mm) door size
Device Length - Long 4′ (1219mm) 2′9″ to 4′ (1145mm to 1219mm) door size

Minimum Stile Requirements

Back to top

4″ escutcheon trims & 4 1/2″ for thumbpiece and rose trims.

Double Door   –  4 1/2″ Min. Stile


239 Strike  –  418 Mullion


239 Strike  –  424 Mullion
                          4 5/8″ Min. Stile

Single Door  –  4 1/2″ Min. Stile


9860 & F9860 Series

Back to top

Dimensions

Back to top

Touchbar height to finished floor 41″ (1043mm) at center
Touch bar projection - neutral 2 1/2″ (64mm)
Touch Bar Projection - depressed 1 3/4″ (45mm)
center case 8 1/2″ x 2 1/2″ x 2″ (216mm x 69mm x 52mm)
Device length - Short 3′ (914mm) 2′2″ x 3′ (840mm to 914mm) door size
Device Length - Long 4′ (1219mm) 2′9″ to 4′ (1145mm to 1219mm) door size
panic grade top & bottom latch case 3 15/16″ x 2 1/8″ x 1 3/8″ (100mm x 52mm x 42mm)
Fire Grade top latch case 3 15/6″ x 2 11/16″ x 2 1/16″ (100mm x 68mm x 53mm)
Fire grade Bottom latch case 3 15/16″ x 2 1/8″ x 1 3/8″ (100mm x 52mm x 42mm)
Top and bottom rod length for 36″ x 84″ doors top rod 43 1/4″ (1100mm), bottom rod 37 3/4″ (960mm)
top and bottom rod length for 48″ x 96″ doors top rod 53 1/16″ (1350mm), bottom rod 37 3/4″ (960mm)
vertical rods 1/2″ (13mm) round tubing

Minimum Stile Requirements

Back to top

Double door - with two vertical rod type exit devices.


3 1/2″ Min. Stile


LBR 9860 & F9860 Series

Back to top

Specifications:

Back to top

  • LBR - No bottom strike. Free access for wheel chairs, stretcher and cars therefore eliminates tripping potential and disfiguration of floors due to dragging of bottom bolts.
  • For Doors - 1-3/4" standard. 3-3/4" minimum stile width required for single door application. 3-1/2" minimum stile width required for double door application. Lever, thumbpiece and escutcheon trims available.
  • Chassis - Nonferrous ally (Panic Grade), steel (Fire Grade)
  • Cover - Brass, bronze or stainless steel. Covers stock hollow metal doors with 161 cutout.
  • Mounting - Furnished with wood and machine screws. Thru bolts are standard packaging on fire rated devices.  Thru bolts are included and standard packaging on fire rated devices.
  • End Cap - Brass, bronze or stainless steel construction.
  • Alarm - Available. Prefix "Alrm" before part #.
  • Hand - Easily field reversible. Specify at time of order LHRB, RHRB for convenience.
  • Latch Bolt - Stainless steel
  • Spring - Stainless steel.
  • Auxillary Spring Latch - Auxiliary spring loaded latchbolt is installed in the lower edge of eh door, when exposed to fire latchbolt releases keeping the door closed and regulated.
  • ANSI Standard - A156.3, Grade 1.
  • Rail Assembly - Heavy gauge brass, bronze or stainless steel.
  • Strike - See Strike page.
  • Dogging Feature - Allen-type key furnished standard on non-fire labeled devices. Cylinder dogging available.
  • UL and ULC Listed - All Series for panic. LBR Series for fire exit hardware for all types of 8′ x 8′ double doors including double egress for up to 3 hour metal, 1-1/2" hour wood doors fire labeled installations. Conforms to standards UL10C and UBC 7-2-1997 codes.
  • Finish - Architectural plated finishes. See bottom of Alarm Exit Hardware for available finishes.
  • Door Size - LBR 9860V3684 and LBR F9860V3684 for 36" x 84" doors. LBR 9880V4896 and LBR F9880V4896 for 48" x 96" doors. LBR 9890V3696 and LBR F9890V3696 for 36" x 96" doors.

Dimensions:

Back to top

Touchbar height to finished floor 41" (1043mm) at center
Touch bar projection - neutral 2 1/2" (64mm)
Touch Bar Projection - depressed 1 3/4" (45mm)
center case 8 1/2" x 2 1/2" x 2" (216mm x 69mm x 52mm)
Device length - Short 3′ (914mm) 2′2" x 3′ (840mm to 914mm) door size
Device Length - Long 4′ (1219mm) 2′9" to 4′ (1145mm to 1219mm) door size
panic grade top & bottom latch case 3 15/16" x 2 1/8" x 1 3/8" (100mm x 52mm x 42mm)
Fire Grade top latch case 3 15/6" x 2 11/16" x 2 1/16" (100mm x 68mm x 53mm)
Top rod length for 36" x 84" doors top rod 43 1/4" (1100mm)
top rod length for 48" x 96" doors top rod 53 1/16" (1350mm)
vertical rods 1/2" (13mm) round tubing

Minimum Stile Requirements

Back to top

Double door - with two vertical rod type exit devices.


3 1/2" Min. Stile

Selector Chart:

Back to top

Single Door Pairs of Doors without Mullion

Vertical Rod Type or Rim Type

2 Vertical Rod Type
Surface applied 2 point lock. Surface application. Surface applied 2 point locking both doors. Each door active same direction. Do not use with overlapping astragal.
Pairs of Doors with Mullion Pairs of Doors without Mullion

2 Rim Type With Mullion

1 Vertical Rod and 1 rim Type
Two independent active doors with full double door openings when required. Same direction. Both devices are surface applied. A coordinator and overlapping strike is recommended.
Pairs of doors without Mullion Handing

2 Vertical Rod type
Double egress surface applied. 2 point locking both doors opposite directions.

Fire Exit Hardware

Back to top

Fire Exit Hardware UL Fire Door Rating
Application Model # Maximum Door Opening ( A ) 3 Hour
Single Doors
Rim Type
F9800EO36
F9820EO48
4′ 0" x 8′ 0" X
Pairs of Doors
Two surface mounted standard vertical rod type or less bottom rod (LBR) Application. Prefix LBR before Part #

a) Swinging in same direction
b) Swinging in opposite Direction (Double Egress)

F9860V3684
X
F9860V3684
8′ 0" x 7′ 2" X
F9890V3696
X
F9890V3696

F9880V4896
X
F9880V4896

8′ 0" x 8′ 0" X
Pairs of Doors
Two rim type with mullion
F9800EO36
F9820EO48
8′ 0" x 8′ 0" X
All fire rated exit devices in all applications, are also labeled for (B) 1-1/2 hour, (C) 3/4 hour, (D) 1 hour, (E) 3/4 hour. All fire exit hardware meet UL10C and UBC 7-2-1997 codes.

Lever Design

Back to top

  • Non handed Grade 1 (Clutch Style)
  • Cylindrical body hardened steel heavy duty tailpiece. For 1 3/4" and 2 1/4" doors. Prefix THI before part number for 2 1/4" door thickness. Available for fire and non fire rated rim and vertical rod exit devices.
  • Rose diameter 3 1/3", lever length 4 3/4". Fits and covers 161 cutout.
Lever Design    
   
   
TUB Design  
 
  • ENTOOL or ICENTOOL  - Entrance
    • Key retracts latchbolt, unlocks lever.
    • ANSI Function - 08
  • STRO5L or ICSTRO5l  - Storeroom
    • Key operates lever, otherwise always locked.
    • ANSI Function - 04
  • PAS30L - Passage
    • Trim always operable and free
    • ANSI Function - 15
  • DUM40L - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10

When ordering "AT" and "SPA" designs, prefix design name before part number. Example: ENTOOL in "AT" design is ATENTOOL.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

Escutcheon Lever Design

Construction

Grade 1, thrubolted design, clutch freewheeling. Non handed design. Easily field reversible. Hardened steel heavy duty tailpiece. Available for fire and non fire rated rim and vertical rod exit devices.

Finishes

Architectural plated finishes

Escutcheon Dimensions

2 5/16" width x 8 1/2" length. Lever length: 4 3/4". Fits and covers 2 1/8" 161 cutout.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

 

  • ESC9800 or ICESC9800 - Entrance

    • Key locks or unlocks lever.
    • ANSI Function - 63
  • ESC9805 or ICESC9805  - Storeroom
    • Key retracts latchbolt, otherwise always locked.
    • ANSI Function - 04
  • ESC9830 - Passage
    • Trim always operable and free
    • ANSI Function - 62
  • ESC9840 - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10

Pull Design

Back to top

9800 NL or IC9800NL 9800 DTP 9800 EOP
  • For Rim Devices Only
  • Outside by pull and key.
  • Key retracts latchbolt.
  • ANSI function - 03
  • Covers 161 cutout.
  • Finishes
  • Outside by pull only.
  • Pull when dogged.
  • ANSI Function - 02
  • Covers 161 cutout.
  • Finishes
  • Outside by plate only.
  • ANSI function - 10
  • Covers 161 cutout.
  • Finishes

Thumbpiece Trim

Back to top

  • 98TP00 or IC98TP00 - Entrance
    • Key locks or unlocks thumbpiece.
    • ANSI Function - 63
  • 98TP05 or IC98TP05  - Storeroom
    • Key retracts latchbolt, otherwise always locked.
    • ANSI Function - 04
  • 98TP30 - Passage
    • Trim always operable and free
    • ANSI Function - 62
  • 98TP40 - Dummy
    • Dummy trim. One sided.
    • ANSI Function - 10
Finishes

Architectural plated finishes

Door Thickness

Standard 1 3/4". Prefix THI before part number for 2 1/4 thick doors.

Keyway

Standard 6-pin "C" keyway. Also available in Schlage C-K, Russwin D!, Corbin 60, Sargent LA, Falcon/Weiser E, Arrow, Yale GA, Yale 8, Kwikset. Can also accept Medeco, Assa and Kaba high security cylinders.

Interchangeable Core - Interchangeable core locks will accept compatible 6 or 7 pin cores with Best, Falcon and Arrow. Indicated by "IC"

Strikes

Back to top

(All Strikes are black nylon coated)
For use with 9860 Vertical Rod Exit Device


221
Standard for 9860. Applied to surface of floor or to a flat threshold. Standard packaging.


227
Applied to surface of stop. No mortise required. Standard packaging.


233
Bottom strike. Alternate bottom strike. Flush mounting stainless steel. Furnished with expansion shields. Requires mortise in the floor.

For use with 9800 Rim Type Exit Device


239
For 9800 surface applied. Standard Packaging.

Overlapping Strike


251
Surface applied. Used on inactive leaf for device on active leaf of pair of doors without mullion.

For use with F9860 Vertical Rod Fire Rated Exit Device


245
Surface applied for F9860. Standard packaging.


233
Bottom strike for F9860. Flush mounting stainless steel. Furnished with expansion shields. Required mortise in the floor. Standard packaging.

For use with F9800 Rim Fire Exit Device


245
For F9800 surface applied. Standard Packaging.

Additional Strikes


LFF
Lock Front Filler.


SF
Strike Filler

Accessories
Mullions

Lockable and electric lockable mullions are available on request. 


418 - Removable mullion Aluminum painted ( Prime coat) includes top and bottom retainer supplied as a stock 96" for non fire rated applications.


424 - Fire exit mullion. 2" x 3" steel tubing round corner, iron construction with iron top and bottom retainers. To be used with two rim type devices on two independent active doors with full double door openings.

Additional Rods Cylinder Dogging Kits

Vertical rod for 10 feet high doors available on non fire rated vertical rod devices only. Use part # VRRD-10.

Prefix "CD" before part#. Available for all 9800 Series devices except fore exit hardware. Cylinder dogging with a mortise cylinder is located on the mounting insert locks bolt in retracted position. 27" minimum door width is required.

To order kit only us part# 36CYLD9800 for 36" and 48CYLD9800 for 48" devices. Specify finish.

Glass Bead Shim Kits

801 - For rim type, 1/8" thick
806 - For vertical type, 1/8" thick
812 - For firerated vertical type, 1/8" thick
When exit devices are used with shim kits with outside trim, spindle length thumbpiece and thru bolt length must be increased accordingly.

Alarm Exit Hardware

Back to top

Rim Type Exit Devices

ALRM 9800 EO36 - Alarm rim type 36" door (panic grade)
ALRM 9820 EO48 - Alarm rim type 48" door (panic grade)
FALRM 9800 EO36 - Alarm rim type 36" door (fire grade)
FALRM 9820 EO48 - Alarm rim type 48" door (fire grade)

Vertical Rod Type Exit Devices

Prefix "Alrm" before part #

Features:

  • Alarm units have an internal horn. When the push rail is depressed, the horn sounds to provide an audible means of signaling that the door has been opened and violated.
  • The unit has changeable 2 minute alarm cutoff or manual reset. Preset at factory for 2 minute alarm cut off. Jumper cable is provided to switch to continuous alarm.
  • The key switch to turn the alarm off is a standard 1-1/4" cylinder with "C" keyway. The alarm operates on one standard 9 volt transistor battery. When battery is weak the horn will emit an intermittent signal.
  • Alarmed units are supplied with two switches. One switch monitors the push rail and the other switch monitors the latchbolt for full proof security.
  • Unit includes "emergency exit only. Alarm will sound" decal for application on door or unit.

Finishes

cal-Royal Description BHMA uS Finish Material
P Primecoat 600 uSP Steel
3 Polished Brass, Clear Powder Coat 605 US3 Brass
4 Satin Brass, Clear Powder Coat 606 US4 Brass
9 Polished Bright Bronze 611 US9 Bronze
10 Satin Bronze Clear Powder Coat 612 US10 Bronze
10B Oiled Rubbed Bronze 613 US10B Bronze
26 Polished Bright Chrome 625 US26 Brass
26D Satin Chrome 626 US26D Brass
32 Polished Bright Stainless 628 US32 Stainless Steel
32D Satin Stainless 630 US32D Stainless Steel

Back to the top